Gold M_Grid™

for SOFC / SOEC lab tests reliability and actual cell performances

Gold M_Grid™ is delivered as raw material,

Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesar 1Material: gold 99.99 %; mesh opening: 0.9 x 1.4 mm; M_Grid thickness: 0.08 mm; flat rolled for improved electrical contact; Fiaxell, as manufacturer and supplier delivers gold M_Grid™ in disc, rectangle or any shape on customer’s request

or customized on customer’s request

The gold M_Grid™, have been manufactured and supplied to replace the fragile standard gold mesh, gauze & fabric that can be purchased on the market. Gold M_Grid™ have been designed for SOFC / SOEC testing (in our SOFC test fixture for instance) but can also be used as counter electrode in wet electro-chemistry, PEM fuel cell, redox flow battery and corrosion applications or for the electro-plating and coating industry. 

BAM 1 Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesar.jpgUK, University of Birmingham, D24 mm gold mesh and 0.5 mm gold wire
Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesar 5.jpgAustralia, CSIRO, D30 and D18 mm gold fabric with two 0.5 mm gold wires
Germany, Eifer, D70 and D60 mm gold gauze with 0.5 mm gold wires , up to 6 Amps per wire
U Washington Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesarUSA, University of Washington, D8 mm gold gauze with flat rolled 0.25 mm gold wire
 
TUM Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesarGermany, TUM, 90 X 80 mm gold fabric with 18 wires of Ø 0.5 mm for high current driving
FOM Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesarNetherlands, Differ, 3D construction of gold mesh for infrared spectroscopy on PEM fuel cell
U Toronto Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesarCanada, U-Toronto, gold mesh baskets for wet electrochemistry, D20 X 50 mm, with three 0.5 mm gold wires
UMD Gold grid 1 mesh gauze platinum SOFC PEM wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesarUSA, University of Maryland, D19 and D25 mm gold fabric with D6 mm hole in the center

 

Other references are presented in the reference website page.

Customized gold M_Grid™ are manufactured for intensive use and every day new SOFC / SOEC cell mounting. Robustness is achieved with double layer gold grid welded together with flattened transversal gold wires. Contrary to commercial woven gold mesh, gauze & fabric that unravels and tears on the first test, gold M_Grid™ can be used hundreds of times.

Fiaxell is the manufacturer and supplier of the gold M_Grid™, showing higher mechanical and long term test performance than standard gold mesh, gauze & fabric available on the market place. 

Why using gold M_Grid™ in SOFC / SOEC fuel cell research field ?

Gold (mesh, gauze, fabric & grid) does not interact with the SOFC / SOEC air electrodes and gives the actual cathode performances contrary to silver or platinum that act as a catalyst and artificially improve the results (see graph below by Steve Simner et. al.).

Platinum and gold mesh contacted to the cathode with Pt (or Au) paste (verified with 3+ tests). Steve Simner et. al (Page 16-19 of PNNL Cathode Development- SECA CTP Review 2005)
PtOx migration to SDC-LSF interface can be observed, platinum acts as a catalyst, contrary to gold which is inert and does not interact with the cathode material.
 

Download the brochure:

Gold grid 1 mesh gauze platinum SOFC PEM SOEC electrolyser wet electrochemistry counter electrodes fuel cell wire fil platine pt or au toile tissu manufacturer fabricant supplier heraeus advent goodfellows AlfaAesar american element fuell cell

Click on the picture to download the gold M_Grid™ technical spec & data sheet or click here to go to all Fiaxell catalog 

Stay informed

Subscribe to the newsletters & get special discounts

Address

Fiaxell 
SOFC Technologies
PSE A
1015 Lausanne
Switzerland

More information

Contact details

Phone (lab): +41 78 677 56 05
Phone (admin): +41 21 647 48 38

  info@fiaxell.com
  Follow us on Linkedin

Privacy policy

Contact Us